Add to Cart
Professional MQY-200 Diesel Smoke Meter /Opacimeter for Trucks and Cars
Product Introduction
Adopting the principle of sampling style (split type) measurement
Measure the opacity of motor vehicle exhaust emissions
Complies with the requirements of GB 3847 "Limits and Measurement Methods for Pollutant Emissions from Diesel Vehicles (Free Acceleration Method and Load Deceleration Method)" for transmission type smoke meters.
Suitable for use by environmental protection departments, motor vehicle inspection stations, automobile manufacturers, automobile repair shops, and other units.
Product Features
1) Adopting "air curtain" protection technology to protect the optical system from smoke pollution. Temperature control in the measurement room to prevent condensation of water in the exhaust, which may affect the measurement results.
2) It has functions such as real-time testing and free acceleration testing.
3) Equipped with oil temperature testing function.
4) Large screen LCD display with clear fonts.
5) Adopting graphical display, user-friendly interface.
6) Equipped with RS232 interface for communication with external computers.
7) Optional built-in micro printer.
8) Optional speed analyzer can be equipped to measure engine speed.
Technical Data | ||||
ITEM | Resolution | Measurement Range | Absolute Accuracy | Relative Accuracy |
Opacity(N) | 0.01% | 0-99.90% | ±2% | |
Optical Absorption Coefficient(K) | 0.01m-1 | 0- 16.08m-1 | 0.05m-1 | |
RPM | 1rpm | 300-9999ppm | 50rpm | |
Oil Temperature | 1℃ | 0-200℃ | ±5℃ | |
Gas Temperature | 1℃ | 0-150℃ | ±5℃ | |
Warm up time | Less than 15 min (5 min warm up for urgent measurement) | |||
Power Supply: | AC 220V±10%,50±1Hz,250W | |||
Efficient length of Optical Path | 215mm | |||
Net Weight | 5kg(Control unit) 7kg(Measure unit) | |||
Dimension(W*H*D) | Control unit: 35.3*21*24.8cm Measure unit: 43*26*17.5cm | |||
Package Dimension | Carton:51.5*50*36cm |
Maintenance and servicing:
1. After the product is used for three months, please disassemble the platform panel and add calcium-base lubrication grease to the guide seat with a pressure rod type oil gun to lubricate the guide sleeve and guide pillar. And also check if the fastening bolts of guide seat and oil cylinder etc. components are loose.
2. Please check the oil level in the oil tank of hydraulic station. Add N46 engine oil (old standard is 30# engine oil) if the oil volume is insufficient.
3. In case the oil pipe of hydraulic system is broken and the oil sprays outside, please stop the operation immediately and carry out maintenance. Do not block the broken place with hands. Otherwise the high pressure oil may injure persons.
Q1. What is your terms of packing?
A: Generally, we pack our goods in wooden case per set
Q2. What is your terms of payment?
A: T/T 50% as deposit, and 50% before delivery. We'll show you the photos of the products and packages
before you pay the balance.
Q3. What is your terms of delivery?
A: EXW, FOB
Q4. How about your delivery time?
A: Generally, it will take 10 or 30 days after receiving your advance payment. The specific delivery time depends
on the items and the quantity of your order.
Q5. Can you produce according to the samples?
A: Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures.
Q6. What is your sample policy?
A: We can supply the sample if we have ready parts in stock, but the customers have to pay the sample cost and
the courier cost.
Q7. Do you test all your goods before delivery?
A: Yes, we have 100% test before delivery
Q8: How do you make our business long-term and good relationship?
A:1. We keep good quality and competitive price to ensure our customers benefit ;
2. We respect every customer as our friend and we sincerely do business and make friends with them,